General

How do I know which system I have?

Select your system according to the following images

What is a Thermode?

Thermode is the device that is attached to the skin of the tested subject for stimulation by heating or cooling

where can find my Medoc Main Station software version number?

In the Launcher screen go to options and click on about Medoc Main Station or
Inside the software go to help and click on about:

Main Station Version

Pathway

How do I know which PATHWAY type I have?

Select your system type according to the following images

Trolly Pathway:

Trolley Pathway

 

 

 

Pathway (Stand alone):

Pathway (stand alone)

How do I know my PATHWAY serial number?

Select your system type according to the following images

Pathway trolley serial number:
Pathway trolley serial number

 

 

 

 

Pathway trolley Serial number:
Pathway trolley Serial number

 

 

 

 

Stand alone PATHWAY Serial number:
Pathway (stand alone)

Where can I find the PATHWAY software version number?

The version number is displayed on the splash screen:

PATHWAY Splash screen
PATHWAY Splash screen
Or Start the PATHWAY program and click Help – About PATHWAY..
-The version number is displayed.
About PATHWAY
About PATHWAY

Where can I find the PATHWAY firmware version number?

Start the PATHWAY program and click Help About PATHWAY.

The firmware version number is displayed:

About PATHWAY2
About PATHWAY

Where can I find the PATHWAY license number?

Start the PATHWAY program. The version number is displayed on the splash screen:

Or Start the PATHWAY program and click Help – About PATHWAY.
-The version number is displayed.

How can I copy PATHWAY error message?

All PATHWAY messages can be easily copied, by using the copy and paste option.

  • Mark the PATHWAY message
  • Right-click the selection
  • From the drop-down list select the Copy option
  • Paste the message where required

How can I save a Black BOX file?

Refer to the Black Box section in the operating manual.

Where can I find the system Log file?

By default, the system Log file is located in the PATHWAY main station folder on your PC.
Browse to: C:\Program Files\MEDOC\Pathway Main Station\Log Files\App

How can I save system information file?

The system information file can be saved, by using the PATHWAY program:
1. Start the PATHWAY program and click Help > About PATHWAY.

About PATHWAY3

 

 

 

 

 

 

 
About PATHWAY

2. Click the Sysinfo button, The generated system information text file is displayed
3. Save the file

How do I know which Thermodes are supported on my system?

Start the PATHWAY program:
The Thermodes supported, according to your license, are displayed on the splash screen.

PATHWAY Splash screen2

PATHWAY splash screen
Start the PATHWAY program and click Help > About PATHWAY… The Thermodes supported, according to your license, are displayed

About PATHWAY4

About PATHWAY

How do I know which Thermodes are connected to the PATHWAY?

Thermodes are divided into several groups, depending on their contact area. Select your thermode type according to the following images:

2
CHEPS standard

Screen-Shot-2014-09-22-at-1.27.29-AM






Almost all thermodes are available in standard and fMRI configurations. Cable length in Standard thermodes is 1.8-2.5 m; fMRI cable length is 10m.

How do I know which accessories are connected to my PATHWAY system?

Select the connected accessories from the following images:

How do I read data from the PATHWAY program status bar?

The PATHWAY program status bar is located at the bottom of the PATHWAY screen.
The available information on the status bar is:

Mode: Demo / On-line
PATHWAY state
COM: Green / Red light according to state
Heater temperature (CHEPS only)
TEC temperature
Water temperature
Safety: Green / Red light according to state

How do I know if main power switch is ON?

When the Main Power switch is ON, it lights up.

PATHWAY Main switch
Main Power switch

How do I know if the Electronic Box switch is ON?

When the Electronic Box switch is ON, it lights up (see behind the guard).

Electronic box switch

How do I know if the ECU switch is ON?

When the ECU switch is ON, it lights up.

ECU switch is ON

How do I find the temperature on the ECU display?

The temperature on the ECU display is located according to the following figures:
On the front panel of the PATHWAY trolley

PATHWAY Trolley ECU display
Pathway Trolley ECU display
On the front panel of the PATHWAY stand-alone ECU
Pathway Stand-alone ECU display

Can I install a PATHWAY Main Station on multiple computers?

YES. The PATHWAY can be installed on as many computers as you like.

Each PATHWAY installation CD can be used to install software that can activate a unique system, according to the license file that is located on the installation CD itself.

Why does the PATHWAY system require licensing?

The license ensures that your system will operate according to your unique requirements.

The PATHWAY system is configured according to your licensing agreement.

I have connected the PATHWAY to the power outlet, but it does not work. What should I do?

Make sure the Main switch is turned ON.

Make sure the Electronic Box switch is turned ON.

Refer to PATHWAY Operating Manual Troubleshooting – Operator Level.

If I face a problem using the system, what should I do?

Refer to the PATHWAY Operating Manual and try to find a solution to your problem.

Contact the Medoc local rep.

Contact the Medoc Service team.

If I face difficulty in calibrating the system, what should I do?

Refer to the PATHWAY Service Manual – Thermode Calibration sections.

What preventive and maintenance procedures should I conduct, and when?

Preventive and Periodical Maintenance procedures are:
Periodical System Run (every two months) – starting system and running Limits-1 test for 10 minutes.
Thermal Calibration (every six months).
System water replacement (if the system is not used for over three months)
Thermode water replacement (if the thermode is not used for over three months)
Water replacement in system with ECU (every month).
Ground conductivity test for fMRI systems (after every assembly in fMRi scanner)
Thermode visual test (prior to attaching to subject) and maintenance at Medoc (every 2 years)

If I face difficulty maintaining the system, what should I do?

Refer to the PATHWAY Operating Manual – Preventive and Periodical Maintenance section.
Contact the Medoc local rep.
Contact the Medoc service team in case you can not find an answer to your difficulty.

Which type of distilled water should be used for system flushing?

Double distilled, by reverse osmosis and ion exchange process (distillation level 0 – 10 microsiemens) should be used

 

Which type of coolant should be used in the system?

DowTHERM SR-1 premixed coolant

 

Using the Pathway system under MR environment

how to solve if Pathway Connector leaks Drops of coolant

TSA-II

How do I know what TSA supported Modes and Add-ons i have in my system?

In the Launcher screen go to options and click on about Medoc Main Station or

Inside the software go to help and click on about:

Supported Add-ons

 

How do I know my TSA-II serial number?

Select your system according to the following images:
TSA-II and TSA-II (-10C) serial number 1 TSA-II and TSA-II (-10C) serial number 2
TSA-II and TSA-II (-10C) serial number
GSA serial number 1 GSA serial number 2
GSA serial number

 

Where can I find the TSA software version number?

In the Launcher screen go to options and click on about Medoc Main Station or

Inside the software go to help and click on about:

Main Station Version

 

Where can I find the Black Box file?

The Black Box file (Blackbox.dat) is located in WinTSA and/or COVAS program directory:

  • WinTSA program black box default location: C: Medoc\WTSA5_XX
  • COVAS program black box default location: C: Medoc\VAS3_XX

How can I save the system information file?

The system information file can be saved via the Utility screen of WinTSA and /or COVAS program.

  • Start the WinTSA or COVAS program.
  • From the toolbar, select the Utility button.
  • Click the System Information button.
  • The generated file Sysinfo.txt is saved under WinTSA or COVAS directory (default location C: Medoc\WTSA5_XX or C: Medoc\VAS3_XX).

How do I know which Thermode is connected to my system?

Thermodes are divided into several groups, depending on their contact area. Select your thermode type according to the following images:

Almost all thermodes are available in standard and fMRI configurations. Cable length in Standard thermodes is 1.8-2.5m; fMRI cable length is 6-12m.

How do I know which accessories are connected to my system?

Select the connected accessories from following images:

How do I read data from program status bar?

The program status bar is located on the upper right corner of the program screen.
CoVAS status bar
CoVAS status bar
WinTSA - WinGSA status bar
WinTSA/WinGSA status bar

The available information on the status bar is:

  • TEMP: Number / Resting / OFF – Temperature of the Thermode contact area.
  • WATER: Number / Resting / OFF – Temperature of the water in the Thermode head.
  • VAS – COVAS slider position (activated in the COVAS program only, if the COVAS accessory is enabled. Replaces WATER)
  • Status: In test / Out of test / Demo

What is an ECU and when should I use it?

 

  • ECU stands for External Cooling Unit (as opposed to Internal Cooling Unit).
  • The ECU is an integral and mandatory part of the TSA-II (-10°C).
  • the ECU should be used with an fMRI-configured TSA-II system.

How do I know if the Main Power Switch is ON?

When the Main Power Switch is ON, it lights up.

TSA-II and TSA-II (-10C) serial number 1 a38-pic02
Main Power switch

How do I know if the Fan is working?

Place your hand in front of TSAII unit cover grid. You should feel air blowing out.

TSA-II fan
TSA-II fan

Why does the system need the Green LED and where can I find it?

The purpose of the Green LED is to illuminate the water-control window in the TSA-II front cover. This improves the control of water level and movement.

  • The Green LED is located in the TSA cooling unit water tank.
TSA-II Green LED
TSA-II Green LED

How do I know if the water is circulating?

Water circulates, when the pump is working.

  • A working pump has specific “tap-tap-tap” noise. When the TSA-II is on, and a program is activated, listen for this noise.
  • When the water circulates, there is a water level movement in the illuminated water window.
    Water movement
    Water movement

I have connected the TSA-II to the power outlet, but it does not work. What should I do?

 

  • Make sure that the Main switch is turned ON.
  • If you have a GSA system make sure that the Isolation transformer switch is turned ON.
  • Refer to the system User and Service Guides, Troubleshooting chapter.

If I face a problem using the system, what should I do?

 

  • Refer to the system User and Service Guides and try to find a solution to your problem.
  • Contact the Medoc local rep.
  • Contact the Medoc Service team.

 

If I face difficulty in calibrating the system, what should I do?

 

  • Contact the Medoc local rep.
  • Contact the Medoc service team in case you can not find an answer to your difficulty.

What Preventive and Maintenance procedures should I conduct, and when?

Preventive and Periodical Maintenance procedures are:

  • Periodical System Run (every two months) – starting system and running Limits-1 test for 10 minutes.
  • Thermal Calibration (every six months).
  • System water replacement (if the system is not used for over three months)
  • Thermode water replacement (if the thermode is not used for over three months)
  • Water replacement in system with ECU (every month).
  • Ground conductivity test for fMRI systems (after every assembly in fMRi scanner)
  • Thermode visual test (prior to attaching to subject) and maintenance at Medoc (every 2 years)

If I face difficulty maintaining the system, what should I do?

Refer to the system User and Service Guides, Calibration section.

If I face difficulty using TTL input/output accessory, what should I do?

TTL input option:
The TSA can be started by an external ±5V, 100-2000msec trigger. The trigger must be set to External in the CoVAS program algorithm.
TTL output option:
TTL output is a ±5V, duration 50-3000msec pulse (set via Utility-»Setup). TTL output must be enabled in the CoVAS program algorithm.
Common TTL input connection
TTL Input Cable connection
TTL Input Cable connection
Contact the Medoc service team in case you can not find an answer to your difficulty.

 

 

Q-Sense

AlgoMed

how to Replace Battery in AlgoMed